Posts

Showing posts with the label IES bits

Important Questions on Control Systems

Image

Multiple Choice Questions on Power Systems - 6

Important Multiple Choice Questions On Power Systems 1.        Plug-setting of a relay can be altered by varying A)      Number of ampere-turns B)       Air gap of magnetic path C)       Adjustable back up stop D)      None of these 2.        If the time of operation of a relay for unity TMS is 10 sec, the time of operation of 0.5 TMS will be A)      20 Sec B)       5 Sec C)       10 Sec D)      None of these 3.        Where the voltages are high and current to be interrupted is low, the breaker proffered is A)      Air blast CB B)       Oil CB C)       Vacuum CB D)      Any of these 4.        Resistance switching is normally employed in A)      All breakers B)       Bulk oil breakers C)       Minimum oil breakers D)      Air blast circuit breakers 5.        For protection of rotating machines against lightning surges a combination of A)      Lighting conductor and capacitors are used B)       Lighting conductor and lighting arrestors

Multiple Choice Questions on Power Systems - 5

Important multiple choice questions on power systems 1.        Which one of the following statements is true? A)      Steady state stability limit is greater than transient state stability limit B)       Steady state stability limit is equal to transient state stability limit C)       Steady state stability limit is less than the transient stability limit D)      No generalisation can be made regarding the equality of otherwise of the steady state stability limit and transient stability limit 2.        If the integral control of a single area system, when  the system frequency error is reduced to zero A)      The integrator output and the speed changer position attains a constant value B)       The integrator output increases but the speed changer position also comes down C)       The integrator output decreases and the speed changer position also comes down D)      The integrator output decreases but the speed changer position moves up 3.        The steady-st

Multiple choice questions on Electrical Machines - 5

Important Multiple Choice Questions On Electrical Machines 1. Supply to one terminal of delta-star three-phase core type transformer which is on no-load fails. Assuming magnetic circuit symmetry, voltages on the secondary side will be 230, 230,115 230,115, 115 345, 115, 115 345, 0, 345 2. A 220/440 V, 50Hz, 5kVA single phase transformer operates on 220V, 40 Hz supply with secondary winding. Then The eddy current loss and hysteresis loss of the transformer decrease The eddy current loss and hysteresis loss of the transformer increase The hysteresis loss of the transformer increases while eddy current loss remains the same The hysteresis loss remains the same whereas eddy current loss decreases 3. The voltage regulation of a large transformer is mainly influenced by No-load current and load power factor Winding resistances and load power factor Leakage fluxes and load power factor Winding resistances and core losses 4. If a sinus

Multiple choice questions on Power Systems- 4

Important Multiple Choice Questions On Power Systems 1. With 100 % inductive shunt compensation, the voltage profile is flat for 100% loading line 50% loading line Zero loading of line None of these 2. For a long uncompensated line the limit to the line loading is governed by Thermal limit Voltage drop Stability limit Corona loss 3. Series capacitive compensation in EHV transmission lines is used to Reduce the line loading Improve   the stability of the system Reduce the voltage profile Improves the protection of the line 4. The main consideration for higher and higher operating voltage of transmission is to Increase the efficiency of transmission Reduce power losses Increase power transmission capability Both (A) and (B) above 5. The inertia constant H of a machine of 200MVA is 2 p.u. its value corresponding to 400MVA will be 4 2 1 0.5 6. A 500MVA, 11kV synchronous generator has 0.2 p.u. synchronous re

Multiple Choice Questions on Power System - 3

Important multiple choice questions on power system 1.        A line trap in carrier current relaying tuned to carrier frequency presents A)      High impedance to carrier frequency but low impedance to power frequency B)       Low impedance to both carrier and power frequency C)       High impedance to both carrier and power frequencies D)      Low impedance to carrier frequency and high impedance to power frequency 2.        The use of fast acting relays and circuit breakers for clearing a sudden short circuit on a transmission link between generator and the receiving end bus improves the transient stability of the machine because A)      Short circuit current becomes zero B)       Post-fault transfer impedance attains a value higher than that during the fault C)       Ordinate of the post-fault power-angle characteristic is higher than that of during fault characteristic D)      Voltage behind the transient reactance increases to a higher value 3.        A